Instruments & Technology
MATERIALS GROWTH AND CHARACTERIZATION LABORATORY
Furnaces for sample growth and treatment
Optical floating zone furnace (Crystal Systems Corp. Japan)
|
Multipurpose induction furnace – horizontal geometry
|
Solid State Electrotransport (SSE)
Characterization techniques
Low-temperature diffractometer
Scanning electron microscope MIRA3 FEG
|
SETSYS Evolution TGA-DTA/DSC SETARAM
Thermal analysis - DSC, DTA, TGA (SETSYS Evolution TGA-DTA/DSC SETARAM).
|
Dilatometer - Netzsch Dil 402C
Supporting equipment
MGCL - Contact
MATERIAL PROPERTIES MEASUREMENT LABORATORY
9T & 30mK
9T & 30mK
![]() |
Cryomagnet 9 T with 3He/4He dilution refrigerator
|
Properties measured at temperatures 30 mK – 400 K and magnetic field up to 9 T: | |
Electrical resistivity | |
AC susceptibility (a. u.) | |
Heat capacity |
PPMS 14T
PPMS 14T
PPMS 14T – Physical Property Measurement System |
Properties measured in magnetic field up to 14 T: |
magnetization - VSM (2 – 1000 K) |
magnetization, susceptibility – AC/DC (0.4 [a.u.] - 2 – 400 K) |
specific heat capacity (0.4 – 400 K) |
thermal conductivity (2 – 400 K) |
Seebeck effect (2 – 400 K) |
electrical resistivity (0.4 – 400 K) |
Hall resistivity (0.4 – 400 K) |
thermal expansion, magnetostriction (2 – 400 K) |
electrical capacity, permitivity (2 – 400 K) |
Properties measured with concurrent application of hydrostatic pressure (p<3GPa): |
electrical resistivity, magnetic susceptibility [a.u.], thermal expansion, heat capacity [a.u.] |
Properties measured with concurrent application of uniaxial pressure: |
electrical resistivity |
PPMS 9T
PPMS 9T
PPMS 9T – Physical Property Measurement System
|
Properties measured in magnetic field up to 9 T: |
magnetization - VSM (2 – 1000 K) |
magnetization, susceptibility – AC/DC (0.4 [a.u.] - 2 – 400 K) |
specific heat capacity (0.4 – 400 K) |
thermal conductivity (2 – 400 K) |
Seebeck effect (2 – 400 K) |
electrical resistivity (0.4 – 400 K) |
Hall resistivity (0.4 – 400 K) |
thermal expansion, magnetostriction (2 – 400 K) |
electrical capacity, permitivity (2 – 400 K) |
Properties measured with concurrent application of hydrostatic pressure (p<3GPa): |
electrical resistivity, magnetic susceptibility [a.u.], thermal expansion, heat capacity [a.u.] |
Properties measured with concurrent application of uniaxial pressure: |
electrical resistivity |
MPMS XL 7T
MPMS XL 7T
![]() |
MPMS XL 7T - Magnetic Property Measurement System
|
Properties measured in fields up to 7 T: | |
magnetic susceptibility (AC) (1.9 - 400K); 0.01 - 1000 Hz, sensitivity 2 x 10-8 emu | |
magnetization (DC) (1.9 - 400K); sensitivity 2 x 10-8 emu | |
magnetoelectric response (1.9 – 400K, -50 - 50V) | |
Properties measured with concurrent application of hydrostatic pressure (p<1GPa): | |
magnetization, magnetic susceptibility | |
Properties measured with concurrent application of uniaxial pressure: | |
magnetization, magnetic susceptibility |
CCR
CCR
|
Closed cycle refrigerator |
Properties measured at temperatures 4 ~ 320 K: | |
Electrical resistivity | |
Themal expansion | |
AC susceptibility (a. u.) | |
Closed cycle apparatus allows us to reach low temperatures (3.5 K) without liquid helium supplies.
|
Pressure cells
Pressure cells
Measurement of properties under pressure
MPML - Contact